powerlab

Bioer Technology

    LineGene 9600

    LineGene 9600 is Bioer technology fluorescence quantitative PCR detection system of the new products. Based on our LineGene family consistent excellent quality, LineGene 9600 to offer you a larger sample size, detection channel more and more wide temperature range. Different from other LineGene family models, model module radiating the patent technology and the bottom of the one and only detect patent gives temperature rate, LineGene 9600 faster temperature accuracy, uniformity and stability of temperature. LineGene 9600 has a large sample size of up to 96 samples and the ultrafast two-color scanning   speed. And a new design of up to eight channels of the LineGene 9600 covering the wavelength range of fluorescence

    detection of all.  

     

    Specification

     

     

    Model

    9620

    9640

    9660

    9680

    Sample Capacity

    96-Well PCR plate,12*8-strip

    96*0.2ml(Bottom Transparent)

    Dynameics Range

    1~1010Copies

    Excitation Wavelength

    300-800nm

    Emission Wavelength

    500-800nm

    Detected   Fluorescence

    F1:FAM,SYBR

    Green I 

    F1:FAM,SYBR

    Green I 

    F1:FAM,SYBR 

    Green I; 

    F1:FAM,SYBR 

    Green I; 

    F1:FAM,SYBR

    Green I 

    F2:VIC,HEX,TET,

    JOE 

    F2:VIC,HEX,TET,

    JOE 

    F2:VIC,HEX,TET,

    JOE, 

    F2:VIC,HEX,TET,

    JOE, 

    F2:VIC,HEX,TET,

    JOE 

     

    F3:Cy3,NED,

    TAMRA, 

    Cy3,NED,TAMRA;

    F3:Cy3,NED,

    TAMRA, 

    F3:CY3,NED,

    TAMRA, 

     

    F4:ROX,    

    TEXAS-RED 

    F3:ROX,    

    TEXAS-RED: 

    F4:ROX,  

    TEXAAS-RED 

    F4:ROX,    

    TEXAS-RED 

     

     

    G4:Cy5;

    F5:Cy5

    F5:Cy5

     

     

     

    F6:Cy5.5

    F6:Cy5.5

     

     

     

     

    F7,F8 for

    Customized 

    Block Temp.Range

    4 ~105 ℃ ( Minimun Increment  :  0.1 ℃ )

    SOAK Low Temp.Consercation Function

    Heating/Colling Rate

    4.0 ℃/s

    Temp.Control Accuracy

    ≤±0.1 ℃

    Temp.Flustuation

    ≤±0.1 ℃

    Temp.Control Mode

    ≤±0.3 ℃

    Sample Volume Range

    BLOCK/Tube Simulation Mode (Automatic Control Based On Sample Volume )

    Gradient Temp.Range

    5 ~100μl

    Hot-lid Temp.Range

    1 ~36 ℃

    Fluorescence Detection

    30 ~110 ℃ (Adjustable, default 105 ℃, Automatic Hot-lid )

    Repeatability

    5%

    Scan Mode

    Entire Plate or Designated Line

    Program

     Max 20 Segments for Each Program, Max 99 Cycles

    Operation Mode

    Continuous

    Scan Period

    5.5s   ( F1/F2 96 Plate Scan)

    Feature Function

    Absolute Quantification 、 Relative Quantification 、SNP Analysis:

    Data Automatic Analysis:Melting Curve;Gradient、Automatic Gain、

    Customized;Multiple File Gene Expression Analysis

    Operation System

    Microsoft  :  Windows2000/XP/vista/windows 7/windows 8

    (Compatible with 64-bit operating system) Software  :  Excel2003/2007

    PC Configuration

    Memory:512M     Hard Disk:10GB    CPU:Pentium® 4    Virtual Memory:≥1000MB

    Power Supply

    100-240V ~ 50/60Hz   600W

    Dimension ( L*W*H )

    430mm*395mm*352mm

    Net Weight

    28kg

    Socket

    USB Adapter, RS232C Adpater ( Optional ),Blue Tooth Adapter ( Optional )

    Certificaters

    Ferrotec Pelitier / Met / CE / RoHS / CE-IVD