powerlab

Molecular Devices

    FilterMax F5

     

    다양한 실험이 가능한 Fiter Based

    Multi-Detection Microplate Reader 

     

    Filter System을 이용하여 ABS, FI, LUM, TRF 및 FP 실험을 수행할 수 있는 High Performance

    Multi-Detection Microplate Reader입니다. 강도 조절이 가능한 고출력 LED Lamp와 UV 파장을

    지원하는 Deuterium Lamp를 광원으로 사용하여 높은 감도와 폭 넓은 Dynamic Range를 제공합니다.

     

     

    ⊙ ABS / FI / LUM / TRF / FP

       ABS (230 - 650 nm)

       FI (230 - 750 nm)

       LUM (400 - 750 nm)

       TRF (340 - 750 nm)

       FP (300 - 750 nm)

    ⊙ LED Lamp (Visible 영역) + Deuterium Lamp (UV 영역)

    ⊙ Top / Bottom Read

    ⊙ 6 ~384 Well Formats

    ⊙ Z-height Optimization (Top Read Only)

    ⊙ Linear/Orbital Shaking

    ⊙ Temp. Control [~45'C]

    ⊙ Endpoint / Kinetic / Well Scan

     

     

    General Specifications

     FilterMax F5FilterMax F5
    Light Source
    High Power LEDs + Deuterium Lamp
    High Power LEDs + Deuterium Lamp
    Detectors
    Silicon Photodiode + PMT
    Filters
    2 EX + 1 EM Filter Slides (6 filter capacity)
    2 EX + 1 EM Filter Slides (6 filter capacity)
    Plate Formats
    6-1536 well
    6-1536 well
    Measurement Methods
    Endpoint, Kinetic, Linear Scan, Area Scan
    Shaking
    Linear + Orbital (3 speeds)
    Temperature Control
    Ambient +4°C to 45°C
    Ambient +4°C to 45°C
    Power/Voltage
    100-240VAC; 50/60Hz
    Dimensions
    39cm W x 24cm H x 58cm L
    Weight
    25 kg
    Fluorescence Intensity (FI) - Top Read
    Wavelength Range
     
    230-750nm
    230-750nm
    Detection Limit--96 well plate
     
    0.5 fmol/200µl fluorescein
    0.5 fmol/200µl fluorescein
    Detection Limit--384 well plate
     
    0.4 fmol/100µl fluorescein
    0.4 fmol/100µl fluorescein
    Linear Dynamic Range
     
    6 decades
    Read Time (Fly mode)
     
    18sec/96well; 37sec/384well
    Fluorescence Intensity (FI) - Bottom Read
    Wavelength Range
     
    300-650nm
    300-650nm
    Detection Limit--96 well plate
     
    25 fmol/200µl fluorescein

    25 fmol/200µl fluorescein
    Detection Limit--384 well plate
     
    15 fmol/100µl fluorescein 
    15 fmol/100µl fluorescein
    Time-Resolved Fluorescence (TRF)
    Wavelength Range
     
    340-750nm
    340-750nm
    Detection Limit--96 well plate
     
    30 amol/200µl Europium
    30 amol/200µl Europium
    Detection Limit--384 well plate
     
    15 amol/100µl Europium
    15 amol/100µl Europium
    Linear Dynamic Range
     
    5 decades
    5 decades
    Read Time (1sec integration)
     
    180sec/96well; 690sec/384well
    180sec/96well; 690sec/384well
    Fluorescence Polarization (FP)
    Wavelength Range
     
    300-750nm
    300-750nm
    Detection Limit--96 well plate
     
    3 mP at 10nM Fluorescein
    3 mP at 10nM Fluorescein
    Detection Limit--384 well plate
     
    4 mP at 10nM Fluorescein
    4 mP at 10nM Fluorescein
    Read Time (Fly mode)
     
    38sec/96well; 79sec/384well
    38sec/96well; 79sec/384well
    Luminescence (LUM) - Glow
    Wavelength Range
     
    400-750nm
     
    400-750nm
    Detection Limit--96 well plate
     
    2 fmol ATP
    Linear Dynamic Range
     
    6 decades
    Read Time (Fly mode)
     
    18sec/96well; 37sec/384well
    Absorbance (Abs)
    Wavelength Range
     
    230-650nm
    230-650nm
    Indication Range
     
    0-3.5 OD
    Accuracy
     
    <+1%+10mOD at 2 OD
    Reproducibility
     
    <+0.5% and +0.005 OD at 2 OD
    Read Time
     
    18sec/96well; 37sec/384well
    Operating System
    CPU
     
    Pentium II 300Mhz
    RAM
     
    128MB min, 256MB recommended
    Hard Drive
     
    150MB free space
    Serial Port
     
    1 free port
    Operating Systems
     
    Windows NT4, 2000, XP