Beckman Coulter
- Avanti JXN-26 High Speed Centirifuge
- Low work surface height for easier installation and unloading of rotors
- Foot pedal for hands-free door operation
- Door swings up and out of the way for easy access to the rotor chamber
- Large digital readouts make operation simpler
- Set and monitor run parameters and email diagnostic results
- Control and monitor the centrifuge from your Apple® iOS and Android™ device with MobileFuge
- Get alerts and diagnostics remotely
- User-friendly, large LCD screen
- View set and actual run conditions simultaneously
- Select rotor by name, not by arcane number code
- 12 accel/13 decel rates
- Delay start
- Run times to 99:59, Hold, and Ω2t integrator for applications that require exquisite reproducibility
- Friction Reduction System (FRS) allows quicker, quieter, and cooler runs
- Uses less energy than traditional centrifuges
- BioSafe* options
- Dynamic rotor inertia check
- High-torque, Switched Reluctance (SR) drive cycle shortens cycle times
- Perfect for shared labs or GMP environments
- On-screen text sensitive "help" screen
- Up to 1000 user-defined programs
- Set up and store numerous protocols
- Password protection for up to 50 unique user profiles
- Network multiple instruments
- Data logging and real-time run graphing
Deceleration: 12 profiles
Width: 71 cm (28 in)
Depth: 86 cm (34 in)
Weight: 290 kg (640 lb.)
Friction Reduction System (FRS): A mechanical rotary vane pump reduces the chamber pressure for improved performance.
Max Capacity Volume Range: 6 liters
Max Speed: 26,000 rpm
Maximum Heat Dissipation into Room under Steady-State Conditions: 1.5 kW (5120 Btu/hr) JA 20 rotor running at 20,000 rpm at 4 degrees C
Noise level at max. speed (approx.): 57 dBA (JA 30.50 Ti rotor with chamber precooled and running at 26,000 rpm).
Refrigeration System: Non-CFC, non-ozone depleting refrigerant
Rotor ID: Automatic
Set Temperature: -10° C to +40° C (in 1° C increments)
Set Time: 99:59, hold
Speed Control: ± 10 rpm of set speed or 0.1%, whichever is greater
Speed Range: 500 to 26,000 rpm or equivalent RCF
Temperature Control: ± 2° C of chamber temperature
Zonal Capability: Yes
Single Tube Sample Volume Range: 1.5 - 1,000 mL
Ambient Temperature Range: 16° C to 38° C
Clearances Required: 7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear
Door: 6.1 cm (2.4 in) thick plastic resin with steel plate
Humidity Restrictions: < 80% (noncondensing)
Pollution Degree: 2
Rotor Chamber Diameter: 51.3 cm (20 in)
Time -- Actual Display: Real-time run monitoring, time elapsed, time remaining, hold
Maximum Force at r max (g): 81,770 x g
Acceleration: 11 profiles
Deceleration: 12 profiles
Increase your productivity.
Ergonomic design
Gain flexibility with MobileFuge
Intuitive interface
Safe and sustainable
Advanced, easy-to-use data management
Simply get results.
High throughput and high productivity are standard fare for every Beckman Coulter centrifuge and the Avanti JXN Series is no exception. It’s more than capable of delivering solutions for shared labs, GMP environments, networked instruments and more.
With the Avanti JXN Series centrifuges, you will not only manage your daily laboratory challenges, but get higher performance, better BioSafety,* and advanced levels of networking. With the MobileFuge app, you can access modern data and user management, remote monitoring, control and error handling via networks, and mobile devices.
Service You Can Count On
Your investment is protected with Beckman Coulter Life Sciences’ service and support. Wherever you are in the world, Beckman Coulter delivers service, troubleshooting, and maintenance when you need it. Highly knowledgeable service professionals solve your problems quickly and efficiently—so you can focus on critical tasks.